VERSION: HyperWare V4.77 2/25/05

Version 4.68 firmware data loggers must be used with HyperWare v4.77.

- Fixed problem with input filtering on xLIM-1 and XLIM-4 which could cause erroneous readings based upon various filtering selections.Product Bulletin: Clarification of HyperLogger/ModuLogger Input Filtering Enhancement, April 18, 2005 Download pdf

- New feature added to allow control of relay output state when logger was stopped.


- Bug fix with XLIM-7 and when certain settling times were selected causing unit to run slowly.


- New menu selection added allowing user to access advanced features.


-Fixed some initialization problems in the scheduler and comparator icons.


VERSION: HyperWare v4.75 11/16/04

- Fixed problem where Real-Time-Trending (RTT) traces were being drawn in an unpredictable manner.

- Made cosmetic adjustments to RTT legend for better visibility.


VERSION: HyperWare v4.74 11/16/04

- Fixed crash when displaying LDC icon messages in status dialog


VERSION: HyperWare v4.73 11/16/04

- Fixed crash when trying to create a file in Post Processing with the same name as an open existing file.

- Fixed Averaging Icon in Post Processing

- Added more elaborate upload checking for icons that require two inputs to be connected.

- Added HLIM-7 information to installed hardware list in the status dialog.

- Removed pager wakeup dialog.

- Removed 0-400mA range in HLIM-4.

- Added RF modem implementation.

- Reorganized lower portion of the status dialog.


VERSION: HyperWare v4.73 07/14/04

- Fixed bug when trying to create a file in Post Processing with the same name as an open existing file.

- Fixed Problems with Averaging Icon in Post Processing

- Added more elaborate upload checking for icons that require two inputs to be connected.

- Added HLIM-7 info to installed hardware list in the status dialog.

- Removed pager wakeup feature.

- Removed 0-400mA range in HLIM-4.

- Added RF modem communication feature.

- Fixed HLP-10 TSA printout information.

- Improved modem initialization strings.

- Changed default modem timeout from 30 sec. to 60 sec.


VERSION: HyperWare v4.70 09/01/03

- Changed delay icon to allow a value of zero for On or Off delay.

- Fixed bug where the communication status brackets would disappear.

- Fine tuned RTT tabular display heading text.

- Changed "H/W" to "Hardware" in status dialog.

- Fixed a problem in the delta icon where state of the "force output" checkbox was not properly retained.

- Changed the default values in the start/stop clock.

- Fixed an error in the start/stop clock icon here it was erroneously indicating that the stop time preceded the start time.

- The multiplexer icon was not taking the name of the upstream icon upon connection.

- The TSA printout was not correct for the ML. Also fixed some other minor TSA text errors.

- Fixed a problem during data DL in rotary mode. Warning box saying that the logger needs to be stopped prior to DL was not being displayed properly.


VERSION: HyperWare v4.70 05/01/03

- Revised and improved operation of programmable interface modules used with Power Sensing Harnesses.

- Corrected communication at 38.4k with older firmware that does not support higher speeds.

- Fixed PD-1 PCMCIA card reader bug when downloading data.

- Improved error messages from Ethernet connection.


VERSION: HyperWare v4.56 07/29/02

- Added fix for installation of two HLIM-9 modules and a new net was created.


VERSION: HyperWare v4.55 07/22/02

- Cards formatted with a PD-2 could not be written by a PD-1 because the 3 files were created as read only. Corrected.

- Baud rate was not getting set in the connect dialog.


VERSION: HyperWare v4.54 06/26/02

- Fixed some problems with the PD-2 BUSY LED

- Minor modification to status bar text relative to the PD-2

- PD-2 data downloads were not working on Win2K. Corrected.


VERSION: HyperWare v4.53 T 06/10/02

- Fixed a problem where loading a net to a card via PD-2 could fail if the net contained HLIM-x input icons. The symptom is a "Net is incompatible" error.

 


VERSION: HyperWare v4.52

- Increased the number of available COM ports from 4 to 32.


VERSION: HyperWare v4.51

- Changed plot colors in Real-time trending. This makes it easier to distinguish different channels.

- Real-time Trending min/max ranges are now saved to ini file on a per channel basis.

- Improved HLIM-9 related text.


VERSION: HyperWare v4.50

- Implemented multiple PIM (programmable Interface Modules) scheme.

- Added PD-2 PCMCIA card reader.

- Increased RS-232 communications speed to 38,400 bps.


VERSION: HyperWare v4.42

- Added New Serial Server (MSS-101) compatibility


VERSION: HyperWare v4.39

- Initial implementation of PD-2, PCMCIA card reader.


VERSION: HyperWare v4.38

- Enhanced multiple delete capability.

- Added Customer PIM implementation


V 4.33 Wave: 2.7-2.8 Released: 7/17/00

- Added Delay icon.

- Added Stopwatch icon.

- Added Scheduler icon.

- Added test of lithium cell voltage upon connection to the logger, a message box is displayed if voltage is low.

- Added validation to pager icon's number of retries. Limited from 1-256

- Added Type-C thermocouple to the post-processing math icon.

- Enabled modem initialization strings.

- Modified context sensitive help for communications dialogs.

- Added multiple delete capability. Holding down the shift button will keep the delete cursor from changing back into the normal cursor.


V 4.29 Wave: 2.7-2.8 Released: 2/16/00 FW: 4.30-4.33 HAP: V1.46

- Enable Pager Wakeup functionality.


V 4.27 Wave: 2.7-2.8 Released: 12/23/99 FW: 4.30 HAP: V1.46

- Added pager wakeup for cell phone.

- Changed the minimum number of samples in all statistics icons from 2 to 1

- Fixed minor problem with Ethernet control enable.


V 4.24 Wave: 2.7-2.8 UNRELEASED FW: 4.20 HAP: V1.46

- Added xLIM-7 Recal to global icon, this also required a new net version.


V 4.19 Wave: 2.7-2.8 UNRELEASED FW: 4.07-4.20 HAP: V1.18-1.4

- Added Remote Constant and Multiplexer Icons


V 4.15 Wave: 2.7-2.8 Released: 3/11/99 FW: 4.07-4.11 HAP: V1.18-1.4

- Modified so that all new nets are in seconds mode as well as log to full and stop

- Modified POI such that the On Time could not be zero.

- Changed POI tab order.


V 4.13 Wave: 2.7-2.8 Released: 11/23/98 FW: 4.07- HAP: V1.18-1.4

- Added Ethernet Connectivity using the Lantronix MSS-1 box.


V 4.10 Wave: 2.7-2.8 Released: 11/16/98 FW: 4.00-4.07 HAP: V1.18-1.2

- Added capability of adjusting HLIM-1 settling times. (Add Settling=1 to Hyperlog section of hyperlog.ini and each HLIM-1 input icon will have an added field where a percentage of the normal settling time can be entered)



V 4.02 Wave: 2.7 Released: 9/11/98 FW: V4.00 HAP: V1.08


- Changed the Max. number of rows in an Excel file convert to 65500 (instead of 16380)

- Added Conventional average capability to Post Processing. This was tested fairly thoroughly and looks good. We will be adding more icons in the near future.

- Modified Real-Time Tracking Scrolling display field widths.


V 4.00 Wave: 2.7 Released: 7/23/98 FW: V4.00 HAP: V1.08

- HyperWare Plotter- Added the capability of selecting either Color or Grayscale printing. (wave.exe V2.7)

- Added changes to Delta, Warning & Average icons for Version compatibility. This ensures that old nets can be opened with new software.

- Added Histogram Icon

- Added Remote Control Icon

- Added HAP Icon

- Added Text Note Icon

- Added Rate of Change Icon

- Added ZERO() function to math icon.

- Modem Detection - Added command to ask the logger is a modem is installed. This command is used during net validation if the net requires a modem.

- Probe values now cannot be fetched if logger is not enabled.

- Added "Force an Output" Option to Delta Icon.

- Added Sliding Average Option to Avg. Icon.

- Added Li

Home | Back to the Top | Site Map

Data Loggers | New Products | Data Logger Applications | Software for Data Loggers | Data Logger Selection Guide
Testimonials | Data Sheets and Downloads | About Logic Beach | Contact Logic Beach |Site Map |Home

Logic Beach, Incorporated
8363-6F Center Drive
La Mesa, CA 91942
Phone: (619) 698-3300