- Field sensor
power... current loops and / or voltage excitation source
- Powered
from system batteries or external power
- Installs
into ModuLogger, Mini and HyperLogger data logging
systems
- Control
input for battery life extending ON/OFF control via logger
software
- Rugged design
to take abusive field conditions
- Field programmable
output voltages..5, 10, 15, and 24Vdc
(custom voltages are available!)
- Low-Power
design for optimum battery life
|
|
|
|
|
Overview
The PSM Power Supply Module is a rugged module that can
be used to provide excitation power for sensors used with
the ModuLogger, Mini and HyperLogger portable and
remote site data logging and alarming systems. The PSM-x
can supply 100mA of current... sufficient to power up to
five 4-20mA loops. Alternatively it can be used as a voltage
source for sensor excitation. One 5Vdc output is standard.
An additional voltage output is available which can be field
jumper programmed in the field for 10, 15 or 24Vdc output
(custom output voltages are available. Contact
Logic Beach.
Four standard packaged versions of the PSM are available
for use with the HyperLogger, ModuLogger and Mini
portable data logging systems. The PSM is offered as a stand-alone
module, or can be incorporated into loggers. The PSM draws
its power from the standard data logger D-cells or an external
supply. For connection to the logger D-cells, a pigtail
with mating connector projects from the PSM. This pigtail
can then be used to connect to the mating connector provided
on the Logic Beach data logger battery pack. Alternatively,
external power can be supplied to the PSM via terminal strip
connections on the PSM.
The PSM outputs are cycled ON/OFF by a low-level control
input from the associated logger. Typically, this control
input is controlled by an output from the associated logger,
providing power only as required for sampling... minimizing
power consumption and maximizing battery life. An LED indicator
lights when the outputs are ON providing visual feedback
of operation during installation.
|
|
Package Configurations
|
| PSM-2 |
MLPSM-2 |
MLBATT-PSM2 |
PSM2-PP |
| The PSM-X is offered in four
standard configurations as specified by the part number. Please
note that special output voltages can be provided for a minimal
additional charge. |
PSM-2:
A metal case housed stand-alone module typically used for
door mounted installation into the HyperLogger system.
The module is equipped with mounting tabs containing threaded
inserts for surface mounting. A pluggable terminal strip provides
for easy connection / disconnection of the control, external
power, and output voltages. |
 |
MLPSM-2:
A PSM mounted into the standard ModuLogger
stacking frame for installation into the ModuLogger or Mini
data logging systems stack. A pluggable terminal strip provides
for easy connection / disconnection of the control, external
power, and output voltages. Typically this model would be
specified if sensor power is desired but the ML-BATT (six
D-cell battery pack option for the ModuLogger or ModuLogger
"Mini") module is not. |
 |
MLBATT-PSM2:
A PSM is incorporated into the standard
ModuLogger / Mini ML-BATT module (six D-cell plug-on battery
pack). A terminal strip provides for easy connection / disconnection
of the control, external power, and output voltages. |
 |
 |
 |
System Specs
| Terminal Strip: |
12 position strip for connection
of external power input, control signal input, and the programmable
and 5 Vdc outputs and ground. |
| Pigtail Connection: |
a pair of pigtails is provided
for direct interface to the HyperLogger, ModuLogger
and Mini battery pack. In the ModuLogger and Mini implementation,
the PSM is wired in series between the battery pack (ML-BATT)
and the CPU module using the two provided pigtails and mating
polarized connectors. |
| Status Indicators |
Output "ON" LED indicator |
| External Power Input: |
8 - 32Vdc input |
| Control Signal Input: |
Field Programmable for Hi Input
= ON or Lo Input = ON
(LO = 0 to 0.5Vdc ; HI = 3 to 20Vdc)
Control current = 400uA at 5 Vdc (On) |
| Power Supply Output #1: |
Programmable Vdc* Output :
Ranges: 10, 15, or 24Vdc (jumper programmable)
Accuracy: +/- 300 mV (special trim available)
Current: 100mA** (short circuit protected) |
| Output #2: |
Fixed 5 Vdc Output:
Accuracy: +/- 150mV
Current: 40mA (short circuit protected) |
| Parasitic Current (Outputs
Off): |
300uA typical |
| Circuit Protection: |
Continuous short circuit protection
on outputs. Reverse polarity protection on inputs |
| Operating Temperature Range: |
-40C to 70C |
* Tighter tolerance and
custom voltage outputs from 7 to 25Vdc available. Contact Logic
Beach for details.
** Current output capability varies as a function of programmed
output voltages due to thermal concerns.
|
|
|
|

Data
Logger Selection Guide | Data Logger Applications | Data Sheets and Downloads | Testimonials | About Logic Beach | Contact
| Sitemap
Logic Beach, Incorporated
8363-6F Center Drive
La Mesa, CA 91942
Phone: (619) 698-3300 |
Fax: (619) 469-8604