DC current
sensors from Logic Beach allow for the indirect, non-invasive
measurement of DC current. We offer a number of split core
and clamp-on style probes with measurement ranges from 20
to 500 Amps. These current sensors provide a DC voltage
or current output which is easily scaled to engineering
units within the data logger using HyperWare, the easy to
use software from Logic Beach.
Applications include monitoring and testing
of: battery chargers, automotive loads, control signals,
UPS battery backups, motor current.
See the Data
Logger Selection Guide for help with locating the appropriate
instrument for your inputs.
|
P/N
LBI-H971
|
Description:
Split-core CT for bi-polar DC current measurement, field adjustable full scale range from +/- 200Adc to +/-20Adc. Output 4-20mA is scaled such that 12mA corresponds to 0Adc. For increased sensitivity, multiple conductor loops can be used. Wire aperature is self-centering (0.8" x 1.1"). -30 to 60C operating temperature. Unique design precludes permanent damage due to over-current (as can be seen by Hall effect devices).
|
|
Range
|
Output
|
Supply Voltage
|
Accuracy
|
Operating Voltage
|
| Field adjustable Full Scale range. +/-20Adc to +/-200Adc via 20 turn adjustment potentiometer. Fixed factory adjusted ranges are available. 25,000Adc withstand.
|
4-20mA; 12mA corresponds to 0Adc current
|
12 to 24Vdc. For currents > 120Adc, minimum 15Vdc required.
|
0 to 100Adc; +/-0.5Adc; 100 to 200Adc +/-0.5%FS
|
600Vdc
|
|
P/N
LBI-H970LC- x(output)
|
Description:
Split core hall effect current
probe. Switch selectable ranges. Dual outputs, specify
A or B for DC range. Wire size: 1.0" x 0.9".
Response time: 2 secs.
|
|
Range-Switch Selectable
|
Output
|
Supply Voltage
|
Accuracy
|
Operating Voltage
|
|
0-20/40/80
|
(A)
4-20mA & 0-5Vdc or (B) 4-20mA&0-10Vdc
|
12-30VAC/VDC
|
3% F.S.
|
650 VAC/850VDC
|
|
P/N
LBI-H970HC-x
(output)
|
Description:
Split core hall effect current
probe. Switch selectable ranges. Dual outputs, specify
A or B for DC range. Wire size: 1.0" x 0.9".
Response time: 2 secs.
|
|
Range-Switch Selectable
|
Output
|
Supply Voltage
|
Accuracy
|
Operating Voltage
|
|
0-50/100/200
|
(A)4- 20mA & 0- 5Vdc or (B)4- 20mA &0- 10Vdc
|
15- 30VAC/VDC
|
3% F.S.
|
650 VAC/850VDC
|
|
P/N
PB-200B
|
Description:
Split-core hall effect clamp-on
current probe. Millivolt output scalable to 0-200
Amps. 6 foot leads. IEC348 Class II rated. LED power
indication.
|
|
Range
|
Output
|
Supply Voltage
|
Accuracy
|
Operating Voltage
|
|
1 - 200
|
10mV
per Amp
|
External 6.5 - 10.5 VDC
|
2-50A
- 2% F.S.
50-200A
- 1% F.S.
|
650 VDC
|
|
|
|

Data