HyperWare-II is for use only with the IntelliLogger products and is NOT
compatible with the HyperLogger and ModuLogger products.

1)     Check HyperWare and Firmware compatibility.

To insure compatibility between releases of HyperWare-II and the firmware running in the IntelliLogger, the version numbers of HyperWare-II and the IntelliLogger firmware  must match as described per the following. 

HyperWare-II Version

To check the current Version Number of your currently installed HyperWare-II, select the Help/About menu choice from the opening Communications Window.

IntelliLogger Firmware Version

To check the current firmware version installed in the IntelliLogger, view the current version via the top line of the LCD on the IntelliLogger or use a Status inquiry via a PC connected to the IntelliLogger via browser or  HyperWare-II.

Version compatibility is dictated by the second number set within the version number.  To be compatible, these numbers must be the same.  For example if the IntelliLogger has version 1.3.4.5 and the HyperWare-II is version 1.3.6.8, then the HyperWare-II and Firmware are compatible as both have the number 3 as the second number set.

2) Download and Install IntelliLogger Firmware

Following is a listing of available downloads.  The currently installed firmware version is viewed via the top line of the IntelliLogger LCD or use a Status inquiry via a PC connected to the IntelliLogger via browser or HyperWare-II.

IntelliLogger Firmware Update Procedure

Step 1: Download and unzip the desired firmware version (below) into a temporary directory. You will have a file named IL_Reflash_Ver_x_x_x_x.bin, the x’s indicate the most recently released version.

Step 2: Start HyperWare-II and connect to the IntelliLogger you wish to reflash. 

Step 3: In the Menu, Select Logger, Reflash Firmware and point to the .bin file you have just downloaded.  Continue for 4-5 minutes to complete the update.  A dialog box will open indicating reflash progress and when completed the message “Reflash Complete” is displayed.

IntelliLogger Firmware Downloads:

Click on the link or right-click and select Save Target As… to download the update.

Version 1.16.2.5  (Released 9-16-08)   Note: Upgrade to Build 2045 of Hyperware when using this.
Version 1.16.4.2  (Released 12-19-08)     Note: Upgrade to Build 2045 of Hyperware when using this.
Version 1.17.3.12  (Released 1-25-09)     Note: Upgrade to Build 2046 of Hyperware when using this.
Version 1.17.3.15  (Released 3-12-09) [Release Notes] Note: Upgrade to Build 2047 of Hyperware when using this.
Version 1.17.3.21  (Released 5-1-09) [Release Notes] Note: Upgrade to Build 2048 of Hyperware when using this.
Version 1.17.4.1  (Released 7-31-09) [Release Notes] Note: Upgrade to Build 2049 of Hyperware when using this.
Version 1.17.5.7  (Released 9-14-09) [Release Notes] Note: Upgrade to Build 2049 of Hyperware when using this.
Version 1.17.5.10  (Released 9-21-09) [Release Notes] Note: Upgrade to Build 2049 of Hyperware when using this.
Version 1.17.5.19  (Released 2-4-10) [Release Notes] Note: Upgrade to Build 2049 of Hyperware when using this.
Version 1.19.1.7  (Released 2-4-10) [Release Notes] Note: Upgrade to Build 2051 of Hyperware when using this.
Version 1.19.2.5  (Released 9-17-10) [Release Notes] Note: Upgrade to Build 2054 of Hyperware when using this.
Version 1.19.3.2  (Released 9-17-10) [Release Notes] Note: Upgrade to Build 2055 of Hyperware when using this.
Version 1.20.1.4  (Released 10-19-11) [Release Notes] Note: Upgrade to Build 2058 of Hyperware when using this.
     

 

3) Download and Install HyperWare-II update

Following is a listing of available downloads of the HyperWare-II software.  HyperWare-II listing is presented by “Build Number”.  The “Build Number” identifies a set of files (any number of which may have been updated) that make up a complete release of HyperWare-II.  To check the Build Number  of your currently installed HyperWare-II, select the Help/About menu choice from the opening Communications Window.

Hyperware-II Update Procedure:

Step 1: Download the HyperWare Build file and save it in a temporary directory.

Step 2: Unzip* the file to a temporary directory.

Step 3: Close HyperWare-II and all other programs. From within the temporary directory run Setup.exe and install the program in the same directory as the original installation. This will keep all current settings available in the newly installed program. This completes the software update.

HyperWare-II Builds Available for Download

BUILD 2042 (RELEASED 10-17-07)  
BUILD 2043 (RELEASED 2-29-08)  
BUILD 2045 (RELEASED 7-3-08)  

BUILD 2046 (RELEASED 1-25-09)

[Release Notes]
BUILD 2047 (RELEASED 3-12-09) [Release Notes]
BUILD 2048 (RELEASED 5-1-09) [Release Notes]
BUILD 2049 (RELEASED 7-29-09) [Release Notes]
BUILD 2051 (RELEASED 5-18-10) [Release Notes]
BUILD 2052 (RELEASED 8-5-10) [Release Notes]
BUILD 2054 (RELEASED 9-17-10) [Release Notes]
BUILD 2055 (RELEASED 11-10-10) [Release Notes]
BUILD 2058 (RELEASED 11-14-11) [Release Notes]

 

*Note: If you have trouble unzipping these files, please visit www.winzip.com for more information.